| Summary | 0003209: PathStock doesn't take Base placement into account for stock "Extent Based" | ||||
| Description | If the Base model is not placed at (0,0,0) a stock solid is generated that does have the proper sizing but is placed at the origin. | ||||
| Steps To Reproduce | create object M change placement of M create Job placement of Stock when using "Extend Base Bound Box" is wrong | ||||
| Tags | No tags attached. | ||||
| FreeCAD Information | |||||
| Date Modified | Username | Field | Change |
|---|---|---|---|
| 2017-10-05 18:34 | mlampert | New Issue | |
| 2017-10-05 18:34 | mlampert | Status | new => assigned |
| 2017-10-05 18:34 | mlampert | Assigned To | => mlampert |
| 2017-10-08 16:48 | wmayer | Status | assigned => closed |
| 2017-10-08 16:48 | wmayer | Resolution | open => fixed |
| 2017-10-08 16:48 | wmayer | Fixed in Version | => 0.17 |
| 2017-10-08 16:48 | wmayer | Note Added: 0010265 |